1.
Laboratory Medicine Online ; : 131-138, 2012.
Article in Korean | WPRIM | ID: wpr-145051

ABSTRACT

BACKGROUND: Tumor markers are used for diagnosing cancers and monitoring responses to cancer therapy. In this study, we evaluated the performance of Lumipulse G1200 (Fujirebio, Japan), a fully automated serum analyzer, for immunoassays of tumor markers. METHODS: We determined the precision and linearity of assays performed using Lumipulse G1200 and the correlation between the results of this and other analyzers used for tumor markers according to the guidelines of the Clinical and Laboratory Standards Institute (CLSI). We used 9 tumor markers, namely, carcinoembryonic antigen, alpha-fetoprotein, cancer antigen 125, cancer antigen 15-3 (CA 15-3), cancer antigen 19-9, prostate specific antigen, protein induced by vitamin K absence or antagonist-II, and pepsinogens I and II. Further, we validated reference intervals using 20 serum samples of healthy individuals. RESULTS: Lumipulse G1200 yielded acceptable precision with total CV0.975 for all markers, except pepsinogen I (0.9569). The reference intervals provided by the manufacturer met the criteria mentioned in the CLSI guideline. CONCLUSIONS: Assays using Lumipulse G1200 had high precision, clinically acceptable linearity, and good correlation with the established assays. This indicates that Lumipulse G1200 can be potentially used in routine laboratories.


Subject(s)
alpha-Fetoproteins , Carcinoembryonic Antigen , Immunoassay , Pepsinogen A , Pepsinogens , Prostate-Specific Antigen , Biomarkers, Tumor , Vitamin K
2.
Laboratory Medicine Online ; : 131-138, 2012.
Article in Korean | WPRIM | ID: wpr-145038

ABSTRACT

BACKGROUND: Tumor markers are used for diagnosing cancers and monitoring responses to cancer therapy. In this study, we evaluated the performance of Lumipulse G1200 (Fujirebio, Japan), a fully automated serum analyzer, for immunoassays of tumor markers. METHODS: We determined the precision and linearity of assays performed using Lumipulse G1200 and the correlation between the results of this and other analyzers used for tumor markers according to the guidelines of the Clinical and Laboratory Standards Institute (CLSI). We used 9 tumor markers, namely, carcinoembryonic antigen, alpha-fetoprotein, cancer antigen 125, cancer antigen 15-3 (CA 15-3), cancer antigen 19-9, prostate specific antigen, protein induced by vitamin K absence or antagonist-II, and pepsinogens I and II. Further, we validated reference intervals using 20 serum samples of healthy individuals. RESULTS: Lumipulse G1200 yielded acceptable precision with total CV0.975 for all markers, except pepsinogen I (0.9569). The reference intervals provided by the manufacturer met the criteria mentioned in the CLSI guideline. CONCLUSIONS: Assays using Lumipulse G1200 had high precision, clinically acceptable linearity, and good correlation with the established assays. This indicates that Lumipulse G1200 can be potentially used in routine laboratories.


Subject(s)
alpha-Fetoproteins , Carcinoembryonic Antigen , Immunoassay , Pepsinogen A , Pepsinogens , Prostate-Specific Antigen , Biomarkers, Tumor , Vitamin K
3.
Journal of Laboratory Medicine and Quality Assurance ; : 95-101, 2011.
Article in Korean | WPRIM | ID: wpr-200543

ABSTRACT

BACKGROUND: We analyzed the positive rates of Mediace Rapid Plasma Reagin (RPR) (Sekisui, Japan) and Mediace Treponema pallidum Latex Agglutination (TPLA) (Sekisui) assays. Positive results were compared to those of immunochromatography assay (ICA) and fluorescent treponemal antibody absorption (FTA-ABS) tests. METHODS: We used samples of patients visited at a university hospital from April 2010 to May 2011. The rates of positive results were calculated with 36,343 RPR results and 5,934 TPLA results. In addition, 237 positive samples with Mediace RPR or TPLA were re-tested with ICA and FTA-ABS. Mediace RPR and TPLA tests were performed with Toshiba 200-FR Neo (Toshiba, Japan). RESULTS: The rates of positive results were 0.47% (169/36,343) and 3.52% (209/5,934) with RPR and TPLA, respectively. Among the 237 sera that tested positive with RPR or TPLA, 76 were RPR(+)/TPLA(+), 28 were RPR(+)/TPLA(-), and 133 were RPR(-)/TPLA(+). When compared to the ICA results, 86.84% (66/76) of the RPR(+)/TPLA(+) sera were ICA(+), 3.57% (1/28) of the RPR(+)/TPLA(-) sera were ICA(+), and 54.89% (73/133) of the RPR(-)/TPLA(+) sera were ICA(+). Only 67.11% of the TPLA(+) sera demonstrated positive FTA-ABS results. However, 100% of the TPLA(-) sera yielded negative FTA-ABS results. ICA and FTA-ABS had a 96.59% positive agreement rate and an 80.68% negative agreement rate. CONCLUSIONS: These results demonstrate that Mediace TPLA has a low positive agreement rate with FTA-ABS. Although Mediace RPR and TPLA have advantages associated with automated methods, positive results should be confirmed with other treponemal tests, due to the high false positive rates.


Subject(s)
Humans , Absorption , Agglutination , Chromatography, Affinity , Latex , Plasma , Syphilis Serodiagnosis , Treponema , Treponema pallidum